Skip to main content
  • Research article
  • Open access
  • Published:

Psychometric properties of the intensive care delirium screening checklist when used by bedside nurses in clinical practice: a prospective descriptive study

Abstract

Background

The Intensive Care Delirium Screening Checklist (ICDSC) demonstrates good psychometric characteristics in research settings. However, evidence about these characteristics in pragmatic ICU settings is inconsistent. This study evaluated psychometric properties and user-friendliness of the ICDSC when administered by ICU nurses in daily practice.

Methods

This prospective study included 77 patients from a surgical intensive care unit. To examine the psychometric characteristics, the scores on the ICDSC (performed by bedside nurses) were compared with the scores on the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) (performed by researchers as gold standard). The user-friendliness was evaluated by 34 ICU nurses with a 20-item questionnaire.

Results

The ICDSC had an area under the curve of 0.843. It showed a good diagnostic accuracy with a sensitivity of 81.0%, a specificity of 87.7%, and a 53.1% positive and 96.4% negative predictive value. The overall Cronbach’s alpha coefficient for all ICDSC scores was high (0.839). Overall, ICU nurses experienced the ICDSC as easy-to-use. The scale was usable in most surgical ICU patients. Yet, some nurses (11.8%) had problems to score the items ‘inappropriate speech’ and ‘symptom fluctuation’ in intubated patients.

Conclusions

The ICDSC is a valid and user-friendly tool for delirium screening in daily ICU nursing practice. Yet, some problems were reported in intubated patients. Therefore, validation studies with specific focus on intubated patients are needed.

Peer Review reports

Background

Delirium, an acute and/or fluctuating disturbance in attention and awareness, in combination with a change in perception or cognition, is a common and serious clinical syndrome in the intensive care unit (ICU) [1,2,3]. Delirium is associated with a poor functional recovery, an increased risk of dementia or mortality, a longer duration of mechanical ventilation, and a prolonged ICU or hospital length of stay [2,3,4,5]. Despite its importance, delirium is poorly noticed by healthcare professionals and its causes are thus undertreated [6,7,8]. Hence, routine delirium screening in ICU patients using a validated screening tool has been recommended [9].

Several screening tools for improving delirium recognition in the ICU have been developed. Based on systematic reviews [10,11,12] and the guidelines of the Society of Critical Care Medicine Pain, Agitation and Delirium (PAD) [9], the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) [13] and the Intensive Care Delirium Screening Checklist (ICDSC) [14] are advised for delirium screening in the ICU. Both tools are valid for delirium detection in ICU research settings. However, when CAM-ICU assessments were performed by nurses in clinical practice, the sensitivity of the tool is low which limits its use as a screening tool [15, 16]. Moreover, some additional disadvantages have been identified including the fact that CAM-ICU ratings are based on observations at one time-point using additional tests (i.e. attention screening examination) and the requirement for extensive training. The ICDSC with its good sensitivity (range, 64–99%, depending on the used cutoff values) and its continuous scoring system based on routine care observations, seems to be useful for delirium screening in daily practice [10, 12, 17]. Yet, lower sensitivity rates (range 43–47%) [15, 18] have been reported, and inconsistencies regarding its optimal cutoff [16, 17, 19, 20] and its use for screening and monitoring the severity of delirium in pragmatic ICU settings remain unclear [3, 8, 21, 22]. Furthermore, the user-friendliness of the ICDSC for bedside nurses in monitoring ICU patients – a prerequisite for implementation in practice - is unexplored. This study aimed to investigate the diagnostic accuracy, concurrent validity and internal consistency of the ICDSC when performed by ICU nurses in clinical practice. The user-friendliness of this scale in observing ICU patients during practice has been evaluated as secondary outcome.

Material and methods

Design, setting and sample

A prospective study was performed on an 18-bed surgical intensive care unit (ICU) of a general hospital in Belgium. Adult patients (18 years or older), Dutch speaking, and consecutively admitted to the hospital for an elective surgery with a planned ICU admission (enrolled during 6 months), were included. Those with severe sensory impairments (i.e. hearing or visual difficulties), neurosurgical indications and expected ICU discharge within 24 h were excluded. Written informed/proxy consent was obtained before study inclusion. Additionally, all ICU nurses of the participating unit were eligible for inclusion. The Medical Ethics Committee of the University Hospitals Leuven approved this study.

Variables

Baseline measurements

Baseline data in patients, collected before surgery using patient interview or based on chart review, were age, sex, marital status, education level, social living circumstances, type of surgery, number of medications, cognitive functioning and presence of confirmed dementia. Cognitive functioning was measured using the 12-item Mini-Mental State Examination (MMSE) [23]. The total sum score varies between 0 and 12, in which lower scores indicate poorer cognitive functioning.

Nurses’ data including age, sex, education level, work experience as a nurse and delirium training received the last 5 years, were collected through a questionnaire.

Delirium and delirium severity

Delirium was both measured with the Intensive Care Delirium Screening Checklist (ICDSC) [14] and the Confusion Assessment Method for the intensive Care Unit (CAM-ICU) [13]. The ICDSC contains 8 items, including level of consciousness; inattention; disorientation; hallucinations; psychomotor activity; speech or mood disturbance; sleep disturbance; and fluctuation of symptoms, which were scored based on observations during each 8-h shift [14]. The level of consciousness was scored as (a) no response/coma, (b) vigorous stimulation/stupor, (c) drowsiness, (d) wakefulness, or (e) hypervigilance. In comatose or stuporose patients, there was no further delirium evaluation during that period. Only patients who were awake were considered as having a normal consciousness, and received no points on that item. The other seven items were rated as absent (0) or present (1), resulting in a total score ranging between 0 and 8. A score of 4 or more indicates delirium [14]. The ICDSC was translated into Flemish by three of the authors (ED, AT, DS), and examined by another member of the research team (KM) and two Dutch-speaking external clinical experts with medical and psychological backgrounds. They all had good knowledge of English and an extensive expertise in delirium.

The CAM-ICU is a diagnostic algorithm for delirium, which was completed based on a cognitive assessment using questions with nonverbal answers and simple commands (e.g. Attention Screening Examination). Delirium was diagnosed when there was a positive rating on the criteria acute onset OR fluctuation, AND inattention AND altered level of consciousness OR disorganized thinking [13]. The level of consciousness was evaluated using the Richmond Agitation-Sedation Scale (RASS) [24]. This scale ranges from − 5 (unarousable) to + 4 (combative). In patients with RASS-score − 5 or − 4, there was no further delirium evaluation at that moment.

The severity of delirium was evaluated using the short form of the Confusion Assessment Method Score for delirium severity (CAM-S) [25], including the four core criteria for delirium. The items ‘inattention’, ‘disorganized thinking’ and ‘altered level of consciousness’ were scored as absent (0), mild (1) or marked (2), the item ‘acute onset or fluctuating course’ as absent (0) or present (1) [25]. The total sum score varies between 0 and 7, in which higher scores indicate a greater severity.

User-friendliness of the ICDSC

The user-friendliness of the ICDSC for the bedside nurses was measured with a 20-item questionnaire (see Table 4 for all aspects measured), and of which the details are reported elsewhere [26, 27].

Procedure

Patients were recruited by one of the three study nurses on the evening before surgery. Afterwards, patient baseline data were collected. Delirium was measured during the first 10 days of ICU hospitalization by bedside and study nurses. Those measurements were performed independently, blinded to the ratings of each other. Bedside nurses administered the ICDSC to score delirium on a twice daily basis (i.e. morning and evening shift). Study nurses performed four assessments (i.e. on postoperative days 2, 3, 5, 9) in enrolled patients, unless patients had an earlier ICU discharge. The assessments took place during the same 8-h shift of the bedside nurses’ ratings, including the performance of the CAM-ICU and CAM-S, as described above. Those CAM-ICU and CAM-S assessments were considered as gold standard. At the end of the patient enrollment period, the bedside nurses received a questionnaire to collect their baseline characteristics and the user-friendliness of the ICDSC. The completion and return of those questionnaire was seen as informed consent.

Both bedside and study nurses were educated in administering the instruments (i.e. CAM-ICU or ICDSC) by two experts in delirium (ED and KM). Study nurses were trained using the manual of CAM-ICU. The education also included the assessment of clinical cases in real practice and follow-up discussion. Interrater reliability for the CAM-ICU (i.e. evaluated in a random sample of 12 paired observations in patients) was κ = 1.00, which indicates perfect agreement. Bedside nurses were trained to rate the ICDSC during a baseline 1-h course followed by three follow-up sessions.

Statistical analysis

To explore patient and nursing data including the data about the user-friendliness of the ICDSC, descriptive analysis (i.e. mean or median and standard deviation or interquartile ranges for continuous data, absolute number and percentages for categorical data) were used.

Paired delirium ratings of bedside and study nurses were evaluated to examine: 1) the diagnostic accuracy of the ICDSC for the CAM-ICU, 2) the level of agreement between the ICDSC and the CAM-ICU, and 3) the concurrent validity between the ICDSC and the CAM-S. Diagnostic accuracy of the ICDSC was explored based on the receiver operating characteristic (ROC) curve in combination with the sensitivity, specificity, positive and negative predictive values for the different cutoffs of the ICDSC. Additionally, “delirious” (positive CAM-ICU and ICDSC score ≥ 4) and “non-delirious” (negative CAM-ICU and ICDSC < 4) patient groups were evaluated using the Cohen’s kappa coefficients (κ), the proportion of observed agreement (P0), prevalence index (PI) and bias index (BI). The P0 express the ratio of exact agreement between the two assessment methods (i.e. CAM-ICU and ICDSC) per total number of assessments, while the κ corrects for chance [28]. Yet, as explained in literature, contradictions in P0 and κ can be seen due to prevalence and bias effects [28]. The concurrent validity between the ICDSC and CAM-S scores was examined with the Spearman’s rho correlation coefficient (i.e. for the total group, and for the delirious and non-delirious group separately).

Finally, internal consistency of the ICDSC was explored with the Cronbach’s alpha and item-total correlations on all ICDSC scores together.

All analysis were two-sided and performed using SPSS version 17.0 (SPSS Inc., Chicago, IL). P-values < 0.05 were considered as significant.

Results

Study sample

One hundred and five patients were consecutively admitted to the hospital for elective surgery with a planned ICU admission. Sixteen of them refused to participate, and another 12 were excluded because there was an expected ICU discharge within 24 h after ICU admission (n = 6), because of severe hearing or visual difficulties (n = 1), or inability to understand Dutch (n = 1). Four patients discontinued the study because they were postoperative not responsive for more than 5 consecutive days (Fig. 1). A total of 77 patients were included in which their baseline data are shown in Table 1. The majority of patients were admitted for coronary artery bypass grafting (CABG) (n = 44, 57.1%) (Table 1).

Fig. 1
figure 1

Overview of the study sample in patients

Table 1 Baseline data of included patients (n = 77)

A maximum of 1540 ICDSC (=77x2x10) and 308 CAM-ICU (=77 × 4) observations were expected to be performed. However, because of a shorter ICU stay or unresponsiveness of included patients during study participation, 508 ICDSC and 168 CAM-ICU observations were completed, generating 143 paired observations. For 25 paired observations, delirium assessments were not performed during the same 8-h shift; and therefore excluded from further analyses.

Of the 49 bedside nurses, 34 of them filled out the questionnaire (i.e. response rate = 69.4%). Their mean age was 29.8 years (±SD 6.3 years). Most of the nurses were female (n = 27, 79.4%), had bachelor degree alone (n = 11, 32.4%) or with an additional degree in intensive care (n = 17, 50.0%), and had more than 6 years of work experience on the intensive care unit (n = 16, 47.1%). Only 4 nurses (12%) followed a training in delirium for the last 5 years.

Post-operative delirium

Postoperative delirium (i.e. minimum one positive CAM-ICU score) occurred in 17 of the 77 patients (22.1%), or in 21 of the 143 paired observations (14.7%). According to the ICDCS, 104 of the 508 observations (20.5%) presented an overall ICDSC score of 4 or more, representing a possible delirium.

Diagnostic accuracy (Table 2)

The ICDSC yielded an area under the ROC curve of 0.873 (95% confidence interval (CI): 0.779–0.966) (Fig. 2). The diagnostic accuracy of the ICDSC with the original cutoff of 4 was good, with 81.0% sensitivity and 87.7% specificity. Bedside nurses detected 17 true-positive delirium observations, 4 false-negative and 15 false-positive observations. This results in a median positive predictive value and a high negative predictive value (Table 2). Lowering the cutoff point to 3 did not increase the sensitivity but reduced the specificity. Increasing the cutoff point to 5 reduced the sensitivity and increased the specificity (Table 2).

Table 2 Diagnostic accuracy of the ICDSC administered by bedside nurses for the CAM-ICU (study nurses) as gold standard in 143 paired observations
Fig. 2
figure 2

ROC curve of the ICDSC scores compared with the CAM-ICU as reference standard. ROC: receiver operating characteristic; ICDSC: Intensive Care Delirium Screening Checklist; CAM-ICU: Confusion Assessment Method for the Intensive Care Unit; Sn: sensitivity; Sp: specificity

ICDSC and CAM-ICU agreement

Agreement in defining delirious and non-delirious patients was moderate (P0 = 0.87; κ = 0.56, 95% CI: 0.38–0.74, p < 0.001), with prevalence and bias indexes of 0.63 and 0.08, respectively.

Concurrent validity ICDSC with CAM-S

Correlation between paired ICDSC scores with CAM-S scores was moderate both for the total group (rspearman = 0.68, p < 0.001) as for the non-delirious subgroup (rspearman = 0.54, P < 0.001). A non-significant correlation between both scales (rspearman = 0.41, p = 0.06) was seen within the delirious group (21 paired observations).

Internal consistency

The overall Cronbach’s alpha coefficient for all the ICDSC scores was 0.839. The alpha coefficients if one of the items was deleted ranged between 0.808 and 0.837 (Table 3). The items correlated strongly (i.e. items 1, 5, 8) (rPearson = 0.604–0.661) to moderately (i.e. items 2, 3, 4, 6, 7) (rPearson = 0.469–0.588) with the sum of the other items (Table 3).

Table 3 Pearson item-total correlation coefficients of the ICDSC (n = 77 patients; 507 test occasions)

User-friendliness

Most respondents mainly or entirely agreed that the concepts of the ICDSC items are clear (n = 33, 97.1%) and compatible with the language used in practice (n = 32, 94.2%). Furthermore, most of them agreed that the way in which the items are defined is free of values and judgement (n = 28, 82.4%), and differences in the response options of the items are mainly or entirely clear (n = 29, 85.3%). Although most nurses mainly or entirely agreed that the ICDSC items in themselves are clear, one nurse mainly disagreed for items 3, 4, 5 and 7 (Table 4), and four nurses mainly disagreed for items 6 (inappropriate speech or mood) and 8 (symptom fluctuation). Rating the two latter items gave problems in intubated patients. Although all nurses mainly or entirely agreed that they had sufficient knowledge from training and experience to evaluate the items on the ICDSC, eleven (32.4%) of them indicated they required help from others to rate the scale. Furthermore, some nurses disagreed that a quickly choice between the possible answers (n = 4, 11.8%) could be made or that the instructions facilitated to choose the correct answers (n = 1, 2.9%). Although 28 nurses (82.4%) mainly or entirely agreed that the ICDSC is a handy instrument to use in practice, 14 nurses (41.2%) mainly disagreed that the instrument adds value to their daily practice. Last, 7 nurses (20.6%) completed the ICDSC ratings in less than 1 min, 23 nurses (67.6%) in 1 to 2 min and 4 nurses (11.8%) in 3 to 5 min.

Table 4 User-friendliness of the ICDSC (n = 34 bedside nurses of the ICU)

Discussion

Although the ICDSC has been advised for delirium screening in the ICU, evidence about its test characteristics with different cutoffs and user-friendliness when performed by bedside nurses is inconsistent [3, 8, 14, 16, 17, 19,20,21,22] This study presents evidence to support the psychometric properties and user-friendliness of the ICDSC used by nurses in clinical practice.

The ICDSC is able to make a good differentiation between patients with and without delirium as compared to the CAM-ICU as reference method. It had good sensitivity and specificity rates when the original cutoff point was used. In contrast with two previous studies [19, 20], lowering the cutoff to 3 would not affect the detection of delirious patients, yet would increase the number of false positives. Increasing the cutoff to 5 would detect less delirious patients, however decrease the number of false positives. Since the ICDSC is used for delirium screening, the original cutoff of 4 remains a good threshold for use in daily ICU practice. The sensitivity is consistent with the validation studies conducted in the research settings (75–99.0%) [16, 17, 19], where a limited number of trained researchers administered the ICDSC. However, compared to the studies evaluated in daily practice (43–71.9%) [8, 18, 20,21,22], sensitivity in our study was higher. This discrepancy may be due to the lack of training [21], the use of a different reference standard [8, 19, 21–23] or caused by the inclusion of other types of ICU patients (e.g. neurosurgery and/or medical (oncology) patients) [8, 18, 21] in these studies.

Agreement between the CAM-ICU and ICDSC was further evaluated with kappa statistics, showing a moderate kappa despite the high observer agreement between both instruments. This difference reflects bias by homogeneity of the sample (prevalence index = 0.63) which reduces the kappa coefficient. However, importantly, the magnitude of kappa was not influenced by a systematically different classification method between the two scales (bias index = 0.08).

The concurrent validity of delirium severity between the ICDSC and the CAM-S was moderate, yet, correlations within the subgroups of nondelirious and delirious patients separately were somewhat lower. Yet, for use as severity instrument in delirious patients, further research testing that specific aspect is necessary. Indeed, the ICDSC was only tested against the CAM-S, which may be insufficiently extensive to evaluate delirium severity. On the other hand, the long form of the CAM-S includes - against the four core items - also the items disorientation, memory impairment, perceptual disturbances, psychomotor agitation/retardation and altered sleep-wake cycles, items also found in the ICDSC [25]. Therefore, further research testing the ICDSC against the full version of the CAM-S is necessary.

Furthermore, reliability analysis revealed good internal consistency with a value which is in line with those in previous studies (0.72–0.86) [19, 21]. Overall, all items showed good item-total correlations and seemed to be worthy of retention.

In general, the user-friendliness of the ICDSC was evaluated as good. Yet, important findings about the ICDSC were identified. First, regarding the clarity of the individual items, none of those items were evaluated as entirely clear for all nurses but, unfortunately, no comments about the perceived difficulties were given. However, four nurses commented that the items ‘inappropriate speech or mood’ and ‘symptom fluctuations’ were difficult to rate in intubated patients. Therefore, these nurses rated the two items as mainly unclear. Hence, we can assume that the difficulties with these two items were not associated with the concepts but with their use in a subpopulation of non-verbally active ICU patients. Yet, one could argue that using the ICDSC in intubated patients affects its psychometric properties. Indeed, a previous study [8] revealed that its sensitivity was lower in a subgroup of non-verbally active patients compared to those in the verbally active subgroup. However, because of the low amount of intubated patient observations in our study (n = 12), sensitivity analysis in this subgroup was not performed. Hence, more research on the ICDSC’s psychometric properties within different subgroups of ICU patients is needed. Second, although all nurses indicated to have appropriate knowledge from training and clinical experience to score the ICDSC items, almost one third indicated the need for help to rate the scale. The reason for this discrepancy cannot be determined as no information regarding the content of the requested help was available. Yet, it indicates that the implementation of the ICDSC in daily practice require more than a simple educational session. Indeed, a comprehensive training session, not only before but also educational support during the implementation process is necessary.

Last, a small majority of nurses agreed that the ICDSC adds value to their nursing practices. One possible reason could be that screening without further action is useless. Indeed, screening should be part of a global delirium management protocol which was not implemented in this study. Because of the small sample size, we were not able to compare the characteristics of nurses who agreed versus those who disagreed. Nevertheless, the importance of delirium evaluation with a screening instrument is well established. Delirium screening based on clinical impressions showed inferior sensitivity compared to screening with a screening tool [8]. Hence, this highlights the need for nursing education about the importance of standard delirium screening with screening tools and its implementation in daily practice. The optimum types of educational strategies should be explored in further research.

Some methodological limitations need to be indicated. First, one might criticize the reference standard we used to diagnose delirium; e.g. the CAM-ICU algorithm rated by the study nurses and not the criteria of the Diagnostic and Statistical Manual of Mental Disorders (5th ed.; DSM-V) evaluated by an experienced physician. Yet, the reliability and validity of this reference standard was warranted because all research nurses followed an extensive training session in delirium using a validated diagnostic model also used in prior research [27, 29, 30], and has been shown to achieve high quality delirium assessments [31]. Second, the analysis regarding accuracy, agreement and validity were based on paired observations in 77 patients, which were not independent. Despite the fact that this might have potentially affected the results, the study was descriptive and not inferential. Yet, it is not expected to be extensively influenced by non-independence. Third, the paired delirium ratings of bedside and research nurses were not performed at the same point in time, which might result in bias because of the fluctuating nature of delirium. Yet, since there are differences in the methods of scoring within the used instruments; ICDSC ratings are scored with observations from the previous 8 h and CAM-ICU/CAM-S ratings are scored with observations made at one time point; evaluating delirium with both methods at the same time was impossible. Yet, by including only the assessments which were made within the same 8-h shift in those analysis, we were able to reduce the time span between the two methods used. Last, one might criticize the used technique for the ICDSC translation into Flemish. However, no gold standard exists [32,33,34]. Instead of performing a back-translation, an expert panel with expertise in delirium was used to check the quality of the translation. This technique was successfully used in previous studies [32,33,34], and is considered to be more effective for ensuring that the translation is performed appropriately [33, 34].

Conclusions

The ICDSC seems to be a valid and user-friendly tool for delirium screening in clinical ICU nursing practice. However, further validation studies with specific focus on intubated patients and on the aspect of monitoring delirium severity are required.

Availability of data and materials

The datasets used and analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

ICU:

Intensive care unit

CAM-ICU:

Confusion Assessment Method for the Intensive Care Unit

ICDSC:

Intensive Care Delirium Screening Checklist

MMSE:

Mini-Mental State Examination

RASS:

Richmond Agitation-Sedation Scale

CAM-S:

Confusion Assessment Method Scale for delirium severity

ROC:

receiving operating chacteristic curve

P0:

Proportion observed agreement

PI:

Prevalence Index

BI:

Bias Index

CABG:

Coronary artery bypass grafting

SD:

Standard deviation

CI:

Confidence interval

AUC:

Area under the curve

DSM-V:

Diagnosis and Statistical Manual of Mental Disorders 5th edition

References

  1. American Psychiatric Association. Neurocognitive disorders. In: Diagnostic and statistical manual of mental disorders. Washington, DC: American Psychiatric Association; 2013. p. 591–643.

    Chapter  Google Scholar 

  2. Mehta S, Cook D, Devlin JW, Skrobik Y, Meade M, Fergusson D, et al. Prevalence, risk factors, and outcomes of delirium in mechanically ventilated adults. Crit Care Med. 2015;43(3):557–66.

    Article  Google Scholar 

  3. Jackson P, Khan A. Delirium in critically ill patients. Crit Care Clin. 2015;31(3):589–603.

    Article  Google Scholar 

  4. Salluh JI, Wang H, Schneider EB, Nagaraja N, Yenokyan G, Damluij A, et al. Outcome of delirium in critically ill patients: systematic review and meta-analysis. BMJ. 2015;350:h2538.

    Article  Google Scholar 

  5. Witlox J, Eurelings LS, de Jonghe JF, Kalisvaart KJ, Eikelenboom P, van Gool WA. Delirium in elderly patients and the risk of postdischarge mortality, institutionalization, and dementia: a meta-analysis. JAMA. 2010;304:443–51.

    Article  CAS  Google Scholar 

  6. Ely EW, Siegel MD, Inouye SK. Delirium in the intensive care unit. An under-recognized syndrome of organ dysfrunction. Semin Respir Crit Care Med. 2001;22:115–26.

    Article  CAS  Google Scholar 

  7. Pun BT, Ely EW. The importance of diagnosing and managing ICU delirium. Chest. 2007;132:624–36.

    Article  Google Scholar 

  8. Van Eijk MMJ, van Marum RJ, Klijn IAM, de Wit N, Kesecioglu J, Slooter AJC. Comparison of delirium assessment tools in a mixed intensive care unit. Crit Care Medicine. 2009;37:1881–5.

    Article  Google Scholar 

  9. Barr J, Fraser GL, Puntillo K, Ely EW, Gélinas C, Dasta JF, et al. Clinical practice guidelines for the management of pain, agitation, and delirium in adult patients in the intensive care unit. Crit Care Med. 2013;41:263–306.

    Article  Google Scholar 

  10. Neto AS, Nassar AP, Cardoso SO, Manetta JA, Pereira VGM, Espósito DC, et al. Delirium screening in critically ill patients: a systematic review and meta-analysis. Crit Care Med. 2012;40:1946–51.

    Article  Google Scholar 

  11. Gusmao-Flores D, Salluh JI, Chalhub RÁ, Quarantini LC. The confusion assessment method for the intensive care unit (CAM-ICU) and intensive care delirium screening checklist (ICDSC) for the diagnosis of delirium: a systematic review and meta-analysis of clinical studies. Crit Care. 2012;16:R115.

    Article  Google Scholar 

  12. Gélinas C, Bérubé M, Chevrier A, Pun BT, Ely EW, Skrobik Y, Barr J. Delirium assessment tools for use in critically ill adults: a psychometric analysis and systematic review. Crit Care Nurse. 2018;38(1):38–49.

    Article  Google Scholar 

  13. Ely EW, Inouye SK, Bernard GR, Gordon S, Francis J, May L, et al. Delirium in mechanically ventilated patients: validity and reliability of the confusion assessment method for the intensive care unit (CAMICU). JAMA. 2001;286:2703–10.

    Article  CAS  Google Scholar 

  14. Bergeron N, Dubois MJ, Dumont M, Dial S, Skrobik Y. Intensive care delirium screening checklist: evaluation of a new screening tool. Intensive Care Med. 2001;27:859–64.

    Article  CAS  Google Scholar 

  15. van Eijk MM, van den Boogaard M, van Marum MJ, Benner P, Eikelenboom P, Honing ML, et al. Routine use of the confusion assessment method for the intensive care unit. A multicenter study. Am J Respir Crit Care Med. 2011;184:340–4.

    Article  Google Scholar 

  16. Larsen L, Frøkjaer VG, Nielsen JS, Skrobik Y, Winkler Y, Møller K, et al. Delirium assessment in neuro-critically ill patients: a validation study. Acta Anaesthesiol Scand. 2019;63:352–9.

    Article  CAS  Google Scholar 

  17. Gusmao-Flores D, Salluh JIF, Dal-Pizzol F, Ritter C, Tomasi CD, Sales Dantas de Lima MA, et al. The validity and reliability of the Portuguese versions of three tools used to diagnose delirium in critically ill patients. Clinics. 2011;66(11):1917–22.

    PubMed  PubMed Central  Google Scholar 

  18. Neufeld KJ, Hayat MJ, Coughlin JM, Huberman AL, Leistikow NA, Krumm SK, et al. Evaluation of two intensive care delirium screening tools for non-critically ill hospitalized patients. Psychosomatics. 2011;52:133–40.

    Article  Google Scholar 

  19. George C, Nair JS, Ebenezer JA, Gangadharan A, ChristuDas A, Gnanaseelan LK, et al. Validation of the intensive care delirium screening checklist in nonintubated intensive care unit patients in a resource-poor medical intensive care setting in South India. J Crit Care. 2011;26:138–43.

    Article  Google Scholar 

  20. Boettger S, Garcia Nuñez D, Meyer R, Richter A, Rudiger A, Schubert M, et al. Screening for delirium with the intensive care delirium screening checklist (ICDSC): a re-evaluation of the threshold for delirium. Swiss Med Wkly. 2018;148:w14597.

    PubMed  Google Scholar 

  21. Kose G, Bolu A, Ozdemir L, Acikel C, Hatipolu S. Reliability and validity of the intensive care delirium screening checklist in Turkish. Int J Nurs Knowl. 2016;27:119–24.

    Article  Google Scholar 

  22. Boettger S, Nuñez DG, Meyer R, Richter A, Fernandez SF, Rudiger A, et al. Delirium in the intensive care setting: a reevaluation of the validity of the CAM-ICU and ICDSC versus the DSM-IV-TR in determining a diagnosis of delirium as part of the daily clinical routine. Palliat Support Care. 2017;15(6):675–83.

    Article  Google Scholar 

  23. Braekhus A, Laake K, Engedal K. The mini-mental state examination: identifying the most efficient variables for detecting cognitive impairment in the elderly. J Am Geriatr Soc. 1992;40:1139–45.

    Article  CAS  Google Scholar 

  24. Sessler CN, Gosnell MS, Grap MJ, Brophy GM, O'Neal PV, Keane KA, et al. The Richmond agitation-sedation scale: validity and reliability in adult intensive care unit patients. Am J Respir Crit Care Med. 2002;166(10):1338–44.

    Article  Google Scholar 

  25. Palihnich K, Inouye SK, Marcantonio ER. The 3D CAM Training Manual for Research. Boston: Hospital Elder Life Program; 2014. www.hospitalelderlifeprogram.org.

    Google Scholar 

  26. Van Gemert LA, Schuurmans MJ. The Neecham confusion scale and the delirium observation screening scale: capacity to discriminate and ease of use in clinical practice. BMC Nurs. 2007;6:3.

    Article  Google Scholar 

  27. Detroyer E, Clement PM, Baeten N, Pennemans M, Decruyenaere M, Vandenberghe J, et al. Detection of delirium in palliative care unit patients: a prospective descriptive study of the delirium observation screening scale administered by bedside nurses. Palliat Med. 2014;28(1):79–86.

    Article  Google Scholar 

  28. Sim J, Wright CC. The kappa statistic in reliability studies: use, interpretation, and sample size requirements. Phys Ther. 2005;85:257–67.

    Article  Google Scholar 

  29. Detroyer E, Dobbels F, Verfaillie E, Meyfroidt G, Sergeant P, Milisen K. Is preoperative anxiety and depression associated with onset of delirium after cardiac surgery in older patients? A prospective cohort study. J Am Geriatr Soc. 2008;56(12):2278–84.

    Article  Google Scholar 

  30. Lemiengre J, Nelis T, Joosten E, Braes T, Foreman M, Gastmans C, et al. Detection of delirium by bedside nurses using the confusion assessment method. J Am Geriatr Soc. 2006;54(4):685–9.

    Article  Google Scholar 

  31. Green JR, Smith J, Taele E, Collinson M, Avidan MS, Schmitt EM, Inouye SK, Young J. Use of the confusion assessment method in multicenter delirium trials: training and standardization. BMC Geriatr. 2019;19:107.

    Article  Google Scholar 

  32. Wellens NIH, Flamaing J, Moons P, Deschodt M, Boonen S, Milisen K. Translation and adaption of the interRAI suite to local requirements in Belgian hospitals. BMC Geriatr. 2012;12:53.

    Article  Google Scholar 

  33. Geisinger KF. Cross-cultural normative assessment: translation and adaptation issues influencing the normative interpretation of assessment instruments. Psychol Assess. 1994;6:304–12.

    Article  Google Scholar 

  34. Cha ES, Kim KH, Erlen JA. Translation of scales in cross-cultural research: issues and techniques. J Adv Nurs. 2007;58:386–95.

    Article  Google Scholar 

Download references

Acknowledgements

The authors would like to thank all nurses and participating patients of the surgical intensive care unit of the Jessa Ziekenhuis, Hasselt, Belgium.

Funding

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.

Author information

Authors and Affiliations

Authors

Contributions

ED, AT, DS, EJ and KM contributed to the study concept and design. ED, AT and DS contributed to the acquisition of data. All authors (ED, AT, DS, GM, JD, AVA, EJ, KM) contributed in the analysis or interpretation of data. ED, AT, DS and KM contributed to the drafting of the article. All authors (ED, AT, DS, GM, JD, AVA, EJ, KM) contributed to revising the article critically for important intellectual content. All authors (ED, AT, DS, GM, JD, AVA, EJ, KM) have read and approved the final draft of the paper. KM supervised the study.

Corresponding author

Correspondence to Koen Milisen.

Ethics declarations

Ethics approval and consent to participate

The study was approved by the Medical Ethics Committee of the University Hospitals Leuven (including the informed/proxy procedure by patients), and written informed consent was obtained by patients before inclusion. Moreover, they were informed about the study, its confidentially and voluntarily nature, and their right to withdraw at any time without consequences for their care. In case of cognitive impairment or diagnosed dementia, the proxy consent procedure was carried out on top of the informed consent procedure. Indeed, as those factors are one of the greatest risk factors for delirium it is important that such patients are included in studies. The bedside nurses received a questionnaire to collect their baseline characteristics and user-friendliness of the ICDSC at the end of the patient enrollment period. The completion and return of those questionnaires was seen as informed consent. The nurses were free to participate, and were informed about the study and the informed consent procedure before the start of the study.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Detroyer, E., Timmermans, A., Segers, D. et al. Psychometric properties of the intensive care delirium screening checklist when used by bedside nurses in clinical practice: a prospective descriptive study. BMC Nurs 19, 21 (2020). https://0-doi-org.brum.beds.ac.uk/10.1186/s12912-020-00415-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12912-020-00415-z

Keywords